Time of PTV is ending, robust optimization comes next - Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Accéder directement au contenu
Article Dans Une Revue Cancer/Radiothérapie Année : 2020

Time of PTV is ending, robust optimization comes next

Résumé

Continuous improvements have been made in the way to prescribe, record and report dose distributions since the therapeutic use of ionizing radiations. The international commission for radiation units and measurement (ICRU) has provided a common language for physicians and physicists to plan and evaluate their treatments. The PTV concept has been used for more than two decades but is becoming obsolete as the CTV-to-PTV margin creates a static dose cloud that does not properly recapitulate all planning vs. delivery uncertainties. The robust optimization concept has recently emerged to overcome the limitations of the PTV concept. This concept is integrated in the inverse planning process and minimizes deviations to planned dose distribution through integration of uncertainties in the planning objectives. It appears critical to account for the uncertainties that are specific to protons and should be accounted for to better exploit the clinical potential of proton therapy. It may also improve treatment quality particularly in hypofractionated photon plans of mobile tumors and more widely to photon radiotherapy. However, in contrast to the PTV concept, a posteriori evaluation of plan quality, called robust evaluation, using error-based scenarios is still warranted. Robust optimization metrics are warranted. These metrics are necessary to compare PTV-based photon and robustly optimized proton plans in general and in model-based NTCP approaches. Assessment of computational demand and approximations of robust optimization algorithms along with metrics to evaluate plan quality are needed but a step further to better prescribe radiotherapy may has been achieved.
Fichier principal
Vignette du fichier
S127832182030189X.pdf (1.06 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03492153 , version 1 (21-09-2022)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

M.-C. Biston, S. Chiavassa, V. Grégoire, J. Thariat, T. Lacornerie. Time of PTV is ending, robust optimization comes next. Cancer/Radiothérapie, 2020, 24, pp.676 - 686. ⟨10.1016/j.canrad.2020.06.016⟩. ⟨hal-03492153⟩
48 Consultations
119 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More